| Case
Study #26 Q-PAC® plastic |
| What the
Project Entailed An Overview: Three odor control scrubbers: One for removal of NH3 and two for removal of H2S. The scrubbers* are part of the sludge handling facility at the Arlington, Virginia Sewage Treatment Plant, located about one mile from the Ronald Reagan Airport, which serves the nation's capital.
Project Scope & Requirements
|
Meeting the Requirements The pressure drop across the packing was also tested. The system designers concluded that the scrubbers packed with Q-PAC® could be easily operated at superficial gas velocities of 10 ft/sec (600 ft/min) or higher and still meet the pressure drop requirements and mass transfer efficiency of 99.5%. This would mean a 30-40% capacity increase in the future. |
|
| *supplied
by COR/PRO, Jacksonville Beach, FL, for HAZEN & SAWYER
**KORB ENGINEERING OF FLORIDA, INC., Ponte Vedra Beach, FL, test report dated May 20, 1998 |
||
Lantec
Products, Inc. E-mail: sales@lantecp.com Sales: 617-302-3269 Headquarters:
818-707-2285 |